Applications

These cables are used indoor operator and subscribers distributıons.

Cable Structure

Inner Conductor

Electrolytic Solid Annealed Copper Wire,
24 AWG, IEC 60228, Class 1

Insulation

Solid PE EN50290-2-23, VDE 0207-2/2YI1

Core Identification

TS IEC 60189-2

Stranding

Cores are twisted in in the form of pairs,
Twisted in the form of layers up to 20 pairs,
and groups of 10 pairs between 30 and 100 pairs

Screen

AL-PES Tape and Solid Tinned Copper Drain Wire

Outer Sheath

PVC Compound, EN 50290-2-22, RAL 7032 Grey

 

Ürün Kodu Damar S./Kesit(mm²) Kablo Çapı(mm)(±5%) Bakır Ağ.(kg/km) ~Kablo Ağ.(kg/km) Standart Uzunluk
43005010 10x2x0,50 7,70 0,00 76,00 500 / 1000
43005020 20x2x0,50 11,60 0,00 143,00 500 / 1000
43005025 25x2x0,50 12,85 0,00 174,00 500 / 1000
43005030 30x2x0,50 15,00 0,00 212,00 500 / 1000
43005050 50x2x0,50 18,50 0,00 335,00 500 / 1000
43005100 100x2x0,50 26,70 0,00 637,00 500 / 1000


CONDUCTOR RESISTANCEINSULATION RESISTANCE
(500 V)
RESISTANCE UNBALANCEDOPERATING VOLTAGE 
(25ºC)
TEST VOLTAGE CORE/COREBEDING 
RADIUS
CHARACTERISTIC IMPEDANCETEMPERATURE RANGEFLAME RETARDANT TESTMUTUAL CAPACITANCE 
(1 KHz)
VELOCITY OF PROPAGATION
Ω/km
97,8
MΩ Km
2000
%3V
250
V
1200
8x DΩ
100+15Ω
-20ºC+60ºCIEC 60332-1-2
VDE 0482-332-1-2
EN 60332-1-2
pF/m
59
%67
10 INSULATION COLOUR WITH IN 10-PAIRS UNIT
PAIRCOLOURPAIRCOLOUR
1Blue/White6Blue / Red
2Orange/White7Orange / Red
3Green/White8Green/Red
4Brown/White9Brown/Red
5Grey/White10Grey/Red
UNIT IDENTIFICATION IEC 60708
UNITCOLOURPAIRCOLOUR
1Blue6White
2Orange7Red
3Green8Black
4Brown9Yellow
5Grey10Violet